PAT Hirschmann Parts

PAT Reel A2B Length Cable Replacement

 Buy Now  

 
PAT REEL A2B LENGTH CABLE REPLACEMENT PROCEDURE

Cut old cable at the cable drum
Disconnect the damaged length cable from junction box at the boom tip.
Open PAT cable reel cover and disconnect wiring from connection block
Pull 7 conductor cable out of strain relief
Remove the PAT Hirschmann cable reel from its mounting brackets.
Remove the damaged length cable […]

By |April 21st, 2016|PAT Hirschmann Parts|Comments Off on PAT Reel A2B Length Cable Replacement

PAT DS50 Troubleshooting for Boom Trucks

 I Need Parts 

 
DS50 Upgrade Brochure

 
PAT DS50 TROUBLESHOOTING – Main Board Connection & Terminal Definitions
X1/X2 (fast-on plug)

System supply (10 – 28V)
System supply (10 – 28V)
System ground
System ground
Relay middle contact
Relay work contact
Relay off position contact
Jumper UEL / HES
Jumper over load relay
Jumper hoist limit switch relay
Periphery supply (10 – 28V)
Digital input_1
Digital input_1
Digital input_2
Digital input_2
Digital input_3
Digital […]

By |April 18th, 2016|Crane Maintenance, PAT Hirschmann Parts|Comments Off on PAT DS50 Troubleshooting for Boom Trucks